Event name
External Encoder Error Warning
Description
The external encoder detected a warning.
EtherCAT Master Function Module Source
Source
Error
Level
attributes
Effects
User program
EtherNet/IP NET RUN
Indicators
System
-defined
variables
Assumed cause
There is insufficient external
encoder power supply voltage.
Noise is entering on the external
Cause and
encoder connector cable.
correction
The external encoder failed.
Attached
None
information
Precautions/
"A8" is displayed on the front panel of the Servo Drive.
Remarks
A - 160
details
Observation
Recovery
Continues.
Operation
Variable
None
Provide the required external
encoder power supply voltage 5
VDC ±5% (4.75 to 5.25 V).
If the motor cable and the external
encoder cable are bundled
together, separate them. Connect
the shield to FG.
If none of the above causes
applies, replace the external
encoder.
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Event code
Slave
Not affected.
EtherNet/IP NET ERR
Data type
Correction
0806 0000 hex
Detection
Continuously
timing
System
Log category
EtherNet/IP LINK/ACT
Name
Prevention
Provide the required external
encoder power supply voltage 5
VDC ±5% (4.75 to 5.25 V).
If the motor cable and the external
encoder cable are bundled
together, separate them. Connect
the shield to FG.
None