Table 6- 1 Fault Codes; Table 6- 2 Warning Codes - Webasto DVS100 Installation, Operation And Maintenance Manual

Mhe intelligent fast charging systems
Hide thumbs Also See for DVS100:
Table of Contents

Advertisement

Code
100
OS System Failure
101
Pilot Int. Failure
102
ADC Failure
103
Invalid Pilot
104
Chrg Vdc Port Low
105
Chrg Vdc Port High
106
BMID Vbat Too Low
107
BMID Vbat Too High
108
Vbat Mismatch
109
Tbat Too High
110
Batt Over-discharge
111
BMID Comm Fail
113
BMID Param Mismatch
114
Powerstage Too Hot
115
Powerstage Shutdown
117
BMID Failure
118
Control Bd Supply
120
Current Too Low
121
ADC Ref Invalid
122
HW Overvolt
123
HW Overcurrent
Code Warning Messages
112
116
119
124
125
126
20182-W-03-01
IMPORTANT INFORMATION – SAVE THESE INSTRUCTIONS

Table 6- 1 Fault Codes

Fault Messages

Table 6- 2 Warning Codes

BMID Config
Early Chrg Term
BMID TmpSnsor Fail
Failed Backup Battery
Maximum Output Current Not
Set
Air System Failure
DVS100 Installation, Operation and Maintenance
Meaning
Power on self test/OS failure
Pilot interrupts stopped occurring
A to D Converter failure
Battery connected with invalid pilot
circuit
Battery voltage too low for charger
Battery voltage too high for charger
Battery voltage too low for BMID
Battery voltage too high for BMID
BMID and terminal voltages don't
match
Battery temp too high
Battery excessively discharged
BMID link lost after charge started
BMID data doesn't match battery
parameters
Powerstage temperature over limit
Powerstage shutdown
autonomously
BMID reporting a critical failure
Control board logic supply failure
Powerstage not producing desired
current
A to D Converter inputs invalid
Overvoltage detected in hardware
Overcurrent detected in hardware
Meaning
BMID data invalid, needs
configuration
Charge terminated
unexpectedly
BMID temp sensor out of valid
range
Battery Backed Up Ram Has
Lost Data
Maximum Output Current Not
Set
No Air Pressure has been
detected.
46