The square mounting holes are 6.5mm X 6.5 mm.
429,3 mm
4.4

Connecting AC (Utility) Power

CAUTION
DANGER
CAUTION
Utility power lines to DVS100 must be provided from an appropriately rated utility distribution panel.
The utility distribution panel must include a "branch" rated circuit breaker (CB). The CB may also
be the "line disconnect" device.
Utility power must be 50/60Hz, 3 phase, 3 wire plus ground. There must be one wire for each
phase plus one earth ground. See Table 4-1 for information on input current, utility requirement,
and cable sizes. All phase wires must be rated for the full input AC current as listed.
20182-W-03-01
IMPORTANT INFORMATION – SAVE THESE INSTRUCTIONS
35,6 mm
53,4 mm
Figure 4- 2 Bolt Pattern for DVS100 Installation
Prior to connecting the unit to the utility ensure that:
The available grounding connection meets all state and local
codes.
The main circuit breaker or other "line disconnect" device is
within sight of the unit and is easily accessible to allow complete
power down of the unit.
Incorrect power wire installation, or failure to properly ground unit
may result in a severe shock hazard.
Use Copper conductors only.
DVS100 Installation, Operation and Maintenance
585 mm
10
Webasto Charging Systems, Inc.