Table 6- 1 Fault Codes - Webasto SVS100 Installation, Operation And Maintenance Manual

Gse intelligent fast charging systems
Table of Contents

Advertisement

Code
100
OS System Failure
101
Pilot Int. Failure
102
ADC Failure
103
Invalid Pilot
104
Chrg Vdc Port Low
105
Chrg Vdc Port High
106
BMID Vbat Too Low
107
BMID Vbat Too High
108
Vbat Mismatch
109
Tbat Too High
110
Batt Over-discharge
111
BMID Comm Fail
113
BMID Param Mismatch
114
Powerstage Too Hot
115
Powerstage Shutdown
117
BMID Failure
118
Control Bd Supply
120
Current Too Low
121
ADC Ref Invalid
122
HW Overvolt
123
HW Overcurrent
23435-W-03-01
SVS100 Installation, Operation and Maintenance Manual

Table 6- 1 Fault Codes

Fault Messages
49
Meaning
Power on self test/OS failure
Pilot interrupts stopped
occurring
A to D Converter failure
Battery connected with invalid
pilot circuit
Battery voltage too low for
charger
Battery voltage too high for
charger
Battery voltage too low for
BMID
Battery voltage too high for
BMID
BMID and terminal voltages
don't match
Battery temp too high
Battery excessively discharged
BMID link lost after charge
started
BMID data doesn't match
battery parameters
Powerstage temperature over
limit
Powerstage shutdown
autonomously
BMID reporting a critical failure
Control board logic supply
failure
Powerstage not producing
desired current
A to D Converter inputs invalid
Overvoltage detected in
hardware
Overcurrent detected in
hardware
Webasto Charging Systems, Inc.

Advertisement

Table of Contents
loading

Table of Contents