Webasto DVS100 Installation, Operation And Maintenance Manual page 9

Mhe intelligent fast charging systems
Hide thumbs Also See for DVS100:
Table of Contents

Advertisement

The unit must be grounded properly with a grounding conductor of size equal to or larger than
that recommended by local electrical codes or the installation section of this manual.
Do not touch the uninsulated portion of the output battery connector or an uninsulated battery
terminal.
Only qualified service personnel may remove the front or back panels on the DVS100. There
are no user serviceable parts inside. Refer all servicing to qualified service personnel. Opening
the system or attempted installation or repair by other than qualified service personnel voids the
warranty.
Disconnect battery charger from input power and battery connections before installing or
servicing. Lockout/tagout input power.
Do not expose to rain or perform installation/service/repair work when in standing water.
A Charge can be stopped by disconnecting the output cable connector or by pressing the stop
button on the front panel. The DVS100 is designed to automatically stop a charge event to
prevent arcing or burning of the charger connections in the event of a hot disconnect.
The charging cables must be sized for the full rated current of the DVS100, and inspected
frequently for wear, cuts and abrasion. Do not use worn, damaged, undersized, or poorly spliced
cable.
The DVS100 charging connector is subject to normal wear and tear, and may be damaged by
misuse or abuse. Frequently inspect the connector for cracking, pitting of contacts, fraying of
wires or signs of connector fatigue. A damaged charging connector should be replaced
immediately.
Do not install or place unit on, over or near combustible surfaces.
Do not install unit near flammables.
Do not block air intake or exhaust.
Ensure that the Battery Monitor/Identifier (BMID) is properly installed according to the BMID
installation instructions.
Replace blown fuses only with same type and rating of fuse.
Do not overload building wiring - be sure power supply system is properly sized, rated and
protected to handle this unit. Use only on circuits provided with the minimum wire size specified
in the installation section.
Protective bollards or Armco barriers should be installed where charging equipment location is
subject to damage from vehicle activity.
Do not install unit where it will be exposed to direct sunlight.
To avoid shock hazard, only install cables approved by PosiCharge™ for indoor use.
Do not subject the cable or coupler to damage or stress. Do not step on the coupler cable.
Do not hang from the coupler cable.
Do not disassemble the DVS100.
20182-W-03-01
IMPORTANT INFORMATION – SAVE THESE INSTRUCTIONS
DVS100 Installation, Operation and Maintenance
3
Webasto Charging Systems, Inc.