Table 6- 1 Fault Codes - Webasto SVS300 Installation, Operation And Maintenance Manual

Mhe intelligent fast charging systems
Table of Contents

Advertisement

SVS-200
Code
100
101
102
103
104
105
106
107
108
109
110
111
113
114
115
117
118
120
121
122
123
20153-W-03-01
IMPORTANT INFORMATION – SAVE THESE INSTRUCTIONS

Table 6- 1 Fault Codes

Fault Messages
OS System Failure
Pilot Int. Failure
ADC Failure
Invalid Pilot
Chrg Vdc Port Low
Chrg Vdc Port High
BMID Vbat Too Low
BMID Vbat Too High
Vbat Mismatch
Tbat Too High
Batt Over-discharge
BMID Comm Fail
BMID Param Mismatch
Powerstage Too Hot
Powerstage Shutdown
BMID Failure
Control Bd Supply
Current Too Low
ADC Ref Invalid
HW Overvolt
HW Overcurrent
Installation, Operation and Maintenance
Meaning
Power on self test/OS failure
Pilot interrupts stopped
occurring
A to D Converter failure
Battery connected with invalid
pilot circuit
Battery voltage too low for
charger
Battery voltage too high for
charger
Battery voltage too low for
BMID
Battery voltage too high for
BMID
BMID and terminal voltages
don't match
Battery temp too high
Battery excessively discharged
BMID link lost after charge
started
BMID data doesn't match
battery parameters
Powerstage temperature over
limit
Powerstage shutdown
autonomously
BMID reporting a critical failure
Control board logic supply
failure
Powerstage not producing
desired current
A to D Converter inputs invalid
Overvoltage detected in
hardware
Overcurrent detected in
hardware
43
Webasto Charging Systems, Inc.

Advertisement

Table of Contents
loading

Table of Contents