Cisco Webex Room Panorama and Room 70 Panorama
Introduction
Cameras PresenterTrack CameraPosition Zoom
Define the zoom position that the presenter tracking camera will move to when the feature
is activated. Only the Precision 60 camera supports presenter tracking.
Requires user role: ADMIN, INTEGRATOR
Default value: 0
Value space: Integer (-65535..65535)
The zoom position.
Cameras PresenterTrack Connector
Define which video input connector the presenter tracking camera is connected to. Only the
Precision 60 camera supports presenter tracking.
Requires user role: ADMIN, INTEGRATOR
Default value: 1
Value space: Integer (1..6)
The video input connector.
Cameras PresenterTrack Enabled
Define whether or not the PresenterTrack feature is available for use. Only the Precision 60
camera supports presenter tracking.
Requires user role: ADMIN, INTEGRATOR
Default value: False
Value space: False/True
False: The PresenterTrack feature is disabled.
True: The PresenterTrack feature is available for use.
D15439.02 Room Panorama and Room 70 Panorama Administrator Guide CE9.14, OCTOBER 2020.
Configuration
Peripherals
Maintenance
Cameras PresenterTrack PresenterDetectedStatus
Define whether to enable or disable automatic switching between the Remote Presenter
and Local Presenter modes in the Briefing room and Classroom scenarios (Room Type
templates). Automatic switching implies that the device switches to Local Presenter mode
when a person is detected in the PresenterTrack trigger zone, and that the device switches
back to the Remote Presenter mode when the local presenter leaves the stage.
If this setting is enabled, the Cameras PresenterTrack PresenterDetected status will be
updated when a new person enters the trigger zone.
Only the Precision 60 camera supports presenter tracking.
Requires user role: ADMIN, INTEGRATOR
Default value: Enabled
Value space: Disabled/Enabled
Disabled: No automatic switching between modes.
Enabled: Automatic switching between the Local Presenter and Remote Presenter
modes.
Cameras PresenterTrack TriggerZone
Define the trigger zone, which corresponds to the area where a person's face must be
detected for presenter tracking to start.
The format is a string of x and y coordinate pairs: "x1,y1,...xn,yn", where the range of x is
(0,1920) and y is (0,1080). Two coordinate pairs define the upper left and lower right corner
of a rectangular trigger zone. More than two coordinate pairs define the vertices of a
polygonal trigger zone.
Only the Precision 60 camera supports presenter tracking.
Requires user role: ADMIN, INTEGRATOR
Default value: ""
Value space: String (0..255)
The coordinates for the trigger zone.