RoomAnalytics settings

RoomAnalytics AmbientNoiseEstimation Interval

Set the interval at which the ambient noise estimation is run, if enabled. The xConfiguration
RoomAnalytics AmbientNoiseEstimation Mode can be used to enable or disable ambient
noise estimations.
Requires user role: ADMIN, INTEGRATOR, USER
Default value: 10
Value space: Integer (10..60)
Set the interval, in seconds, for how often the ambient noise estimation is run.

RoomAnalytics AmbientNoiseEstimation Mode

The device can estimate the stationary ambient noise level (background noise level) in the
room. The result is reported in the RoomAnalytics AmbientNoise Level dBA status. The
status is updated when a new ambient noise level is detected.
Requires user role: ADMIN, INTEGRATOR, USER
Default value: Off
Value space: Off/On
On: The device regularly estimates the stationary ambient noise level.
Off: The device doesn't estimate the stationary ambient noise level.

RoomAnalytics PeopleCountOutOfCall

By using face detection, the device has the capability to find how many persons are in the
room. By default, the device only counts people when in a call, or when displaying the self-
view picture.
Requires user role: ADMIN, INTEGRATOR, USER
Default value: Off
Value space: Off/On
Off: The device counts people only when the device is in a call, or when self-view is on.
On: The device counts people as long as the device is not in standby mode. This
includes outside of call, even if self-view is off.
D15439.02 Room Panorama and Room 70 Panorama Administrator Guide CE9.14, OCTOBER 2020.
Configuration
Peripherals
Maintenance

RoomAnalytics PeoplePresenceDetector

The device has the capability to find whether or not people are present in the room, and
report the result in the RoomAnalytics PeoplePresence status. The feature is based on
ultrasound. Read the status description for more details.
Ultrasound signals for presence detection are not emitted when both this setting AND
the Standby WakeupOnMotionDetection setting are switched Off. The Audio Ultrasound
MaxVolume and Proximity Mode settings has no effect on presence detection.
Requires user role: ADMIN, INTEGRATOR, USER
Default value: Off
Value space: Off/On
Off: Information about the presence of people is not reported in the device's status.
On: Information about the presence of people is reported in the device's status.