e.
Use the Enable remote connection for listening command to display the remote
Dante controlled device responses based on the list of devices provided in the
response in step d. Repeat if necessary for all desired devices.
Example:
Command
wcNetPA-U-xxxxxx*1expr
NOTE: Devices can be set up for listening even if not currently connected to
the DMP unit.
f.
To verify that the DMP is listening to the correct remote devices, use the Query
remote devices being listened to command to display a list of all remote devices
enabled with the command in step 5.
Example:
Command
wlexpr
|
g.
Send the desired command to the amplifier and confirm the correct response is
received.
•
When entering a command, use the "w" character in place of the <Esc> key
and the "pipe" character ( | ) in place of a carriage-return. Failing to do so may
cause the command to fail.
•
The closing bracket ( } ) is necessary to successfully end a command before
attempting to send a new command.
Example:
Command
{dante@NetPA-U-
xxxxxx:wg40000*-
10AU|} }
NOTE: The DMP provides the tag showing the Dante controlled remote device
name while the remote device provides the response for the SIS command.
Response
|
ExprNetPA-U-xxxxxx*1
Response
•
ExprL
NetPA-U-xxxxxx
Response
{dante@NetPA-U-xxxxxx}DsG40000*-
]
10
NetPA Ultra Series • Operation
]
]
26
Need help?