Command
SIS Command
Function
(Host to Device)
Status (continued)
View internal operating
E
temperature status in °C
Verbose mode 2/3
NOTE:
This indicates an internal temperature in the amplifier.
View fault statuses of
E
system
Verbose mode 2/3
X9@
NOTE:
gives an overview of the current status of the amplifier system and channels. Rather than ping every
command gives an overview of the current status of the system and channels.
KEY:
X9!
=
xxx (degrees Celsius) Internal Temperature
X9@
=
Global Fault Status (five digits) —
System Overtemp (53STAT):
Caution: Amplifier functionality has been modified to protect itself.
DC Protect (54STAT):
Service: This may not be a recoverable error; unit may need to be serviced.
Loss of AC (60STAT):
Error: Amplifier, in part or as a whole, has shut down or is misconnected.
Power Supply Fault (61STAT):
Error: Amplifier, in part or as a whole, has shut down or is misconnected.
Standby Status:
Y!
=
Channel Fault Status (five digits) —
Signal Presence (62STAT):
Status: Noteworthy change made to amplifier operation.
Overload (57STAT):
Caution: Amplifier functionality has been modified to protect itself.
Output Thermal Limiting (55STAT):
Caution: Amplifier functionality has been modified to protect itself.
Output Open Circuit (58STAT):
Error: Amplifier, in part or as a whole, has shut down or is misconnected.
Digital Clipping (64STAT):
Caution: Amplifier functionality has been modified to protect itself
Response
(Device to Host)
}
20STAT
X9!]
20Stat
}
X9@
32STAT
32Stat
System Overtemp
n
0
= Not or never detected
0
= Not or never detected
0
= Not or never detected
0
= Not or never detected
0
= unit is active and auto standby timer disabled
1
= auto standby timer running, but not triggered (default)
2
= standby triggered (SIS triggered)
NOTE:
When the standby contact closure is shorted, the unit goes into mode 4 and cannot come out of
mode 4 until the port is no longer shorted. Once the short is removed,the unit goes back to its last known
standby mode and the timer resets
Status: Noteworthy change made to amplifier operation
Signal presence
n
0
= Not present
0
= Not or never detected
0
= Not or never detected
0
= Not or never detected
0
= Not or never detected
X9!]
]
*y1
...y1
1
n
X9@
]
*y1
...y1
1
n
DC Protect
Loss of AC
Power Supply Fault
n
n
n
1
= No longer detected
1
= No longer detected
1
= No longer detected
1
= No longer detected
3
= standby triggered (timer triggered)
4
= standby triggered (contact closure triggered)
Overload
Output thermal limiting
n
n
n
1
= Present
1
= No longer detected
1
= No longer detected
1
= No longer detected
1
= No longer detected
NetPA Ultra Series • Remote Control and Configuration
Additional Description
E
}
##STAT
command, this
Standby Status
n
2
= Detected now
2
= Detected now
2
= Detected now
2
= Detected now
Output open circuit
Digital clipping
n
2
= Detected now
2
= Detected now
2
= Detected now
2
= Detected now
96