1 Turn off power to the target system.
2 Turn off power to the emulation probe.
3 (Optional) Connect the analysis probe to the target system as
4 Plug one end of the ribbon cable into the emulation probe. (In most
5 Plug the other end of the cable into the debug port on the target
CAUTION:
Connecting the Emulator to Your Target System

To connect the emulator to the target system

To connect the emulator to the target system
The emulation or solution User's Guide shows a target interface module and a
50-pin cable. These parts are not needed with the E5900B emulation probe.
The emulator should be connected to the target system using the ribbon cable
provided. For the MPC8xx, two cables are provided. Use the short cable if at
all possible.
described in the User's Guide for your emulation and analysis solution.
cases, the connectors are keyed, so there is only one way to plug them
in.)
system or on the analysis probe.
Be careful to orient the connector as described in the emulation or solution
User's Guide. If the connector is rotated, your target system or the emulator
may be damaged.
For JTAG PowerPC processors (such as the MPC7xx), orient the red stripe
away from pin 1 of the connector and towards the key pin.
For BDM PowerPC processors (such as the MPC8xx), orient the red stripe
toward pin 1.