Emulation Probe Electrical Characteristics - Agilent Technologies E5900B User Manual

Hide thumbs Also See for E5900B:
Table of Contents

Advertisement

Specifications and Characteristics
The following operating characteristics are not specifications, but are typical
operating characteristics for the Agilent Technologies E5900B emulation
probe and E5901B emulation module.

Emulation probe electrical characteristics

Trigger Out SMB Port
With a 50 ohm load, a logic high is >= 2.0 V, and a low is <= 0.4 V. The
output function is selectable
.
Break In SMB Port
Edge-triggered TTL level input, 20 pF, with 4.6k ohms to ground in
parallel. Maximum input: +5 V to -5 V when the trace port analyzer is
powered OFF; +10 V to -5 V when the trace port analyzer is powered
ON. Input function is selectable
.
Communications
Serial Port.
RJ12 connector. Data rate is 9600 baud, 8 bit, no parity, 1 stop
bit.
10/100BASE-T LAN Port.
RJ-45 connector. IEEE 802.3 Type 10BASE-T /
100BASE-TX.
Power Supply
Input.
100-240 V, 1.0 A, 50/60 Hz, IEC 320 connector.
Output.
12 V, 3.3 A
CAT I (Mains isolated). Pollution degree 2.
80
E5900B / E5901B User's Guide Supplement