The prompt indicates the status of the emulation probe:
Emulation probe prompts
U
Running user program
M
Running in background monitor
p
No target power
R
Emulation reset
r
Target reset
c
Checkstop
?
Unknown state
Examples
To set register r0, then view r0 to verify that is was set, enter:
U>rst
M>b
M>reg r0=1234abcd
M>reg r0
reg r0=1234abcd
To break execution then step a single instruction, enter:
U>b
M>s
PC=fff00108
M>
To determine what firmware version is installed in the emulation probe,
enter:
M>ver
Use the help command for more information on these and other commands.
Note that some of commands listed in the help screens are generic commands
for Agilent emulators and may not be available for your product.
If you are writing your own debugger, contact Agilent Technologies for more
information.