Example
To assign an IP address of 192.6.94.2 to the emulation probe, enter the
following command:
R>lan -i 192.6.94.2
Cycle power on the emulation probe so that the new address will take
effect.
9 Verify your emulation probe is now active and on the network. See
"Verifying LAN Communications" on page 38.
Once you have set a valid IP address, you can use the telnet utility to connect
to the emulation probe, and use the lan command to change LAN parameters.

To configure LAN parameters using DHCP

If there is a DHCP server on your network which responds to BOOTP requests
and supports "static allocation" of IP addresses, it can be used to set the trace
port analyzer's LAN parameters.
1 Ask your system administrator to set up an IP address for the
emulation probe on the DHCP server.
You will need to supply the link-level address of the emulation probe.
The link-level address (LLA) is printed on a label above the LAN connector on
the emulation probe. This address is configured in each emulation probe
shipped from the factory and cannot be changed.
2 Connect the LAN cable to the connector on the emulation probe.
3 Cycle power on the emulation probe by powering it off then on again.
4 Wait at least 20 seconds for the emulation probe to receive the IP
address from the DHCP server.
5 Verify that your emulation probe is now active and on the network. See
"To verify LAN communications" on page 38.
E5900B / E5901B User's Guide Supplement
Connecting the Emulation Probe to a LAN
Connecting the Emulation Probe to a Site LAN