5.6. [0x69] RF Reset

The RF-field of the Reader antenna can be switched off for t
Thus, all Transponders which are within the antenna field of the Reader will be reset to their base set-
ting.
Host → Reader
1
5
COM-ADR
Host ← Reader
1
6
COM-ADR
Notes:
• After an RF Reset the Reader is not able to receive a new Transponder before expiration of t
• After an RF Reset, a Transponder which is located within the field must be re-selected.
• The response of this command will be sent after the RF Reset was completed.

5.7. [0x6A] RF ON/OFF

The command RF ON/OFF switches the RF field of the Reader antenna ON and OFF.
Host → Reader
1
6
COM-ADR
Host ← Reader
1
6
COM-ADR
RF:
0x00
RF-Field of Reader antenna is OFF
0x01
RF-Field of Reader antenna is ON
1