0X22] Lock Multiple Blocks - Feig Electronic OBID i-scan ID ISC.MR100 Manual

Standard-reader
Table of Contents

Advertisement

®
OBID i-scan

6.1.3. [0x22] Lock Multiple Blocks

This command locks one or more data blocks.
The supported ISO15693Host commands depends on the different ISO15693 Transponder types,
they are described in chapter
Note:
This command is only available for ISO15693 Transponders and Tag-it HF.
REQUEST-DATA
4
0x22
MODE
RESPONSE-DATA (STATUS = 0x03)
5
DB-ADR-E
RESPONSE-DATA (STATUS = 0x95)
5
ISO15693
DB-ADR-E
ERROR
MODE:
Bit:
Function
ADR:
b000
b001
b010
UID:
Read only serial number of the Transponder. The UID is required only in the addressed mode.
DB-ADR:
First block number to be locked. First block can be any value between 0 and 255.
DB-N:
Number of data blocks to be locked, starting at DB-ADR. The maximum number of DB-N, de-
pends on DB-Size. The maximum number of bytes is 128 byte.
DB-Size
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS = 0x95.
DB-ADR-E:
Block number where the error occurred.
FEIG ELECTRONIC GmbH
System-Manual
9.1. Supported ISO15693 Host commands for ISO15693
5
(6...13)
UID
6
7
6
0
0
non-addressed
addressed
selected
Max. DB-N
4
0x20 ->32
8
0x10 ->16
x
= 128 / x
6 / (14)
7 / (15)
DB-ADR
DB-N
5
4
0
0
Page 56 of 118
ID ISC.MR/PR/PRH100/101-A
3
2
1
0
ADR
H01000-5e-ID-B.doc
Transponders.
0