0X24] Write Multiple Blocks - Feig Electronic OBID i-scan ID ISC.MR100 Manual

Standard-reader
Table of Contents

Advertisement

®
OBID i-scan

6.1.5. [0x24] Write Multiple Blocks

This command writes one or more data blocks.
The supported ISO15693Host commands depends on the different ISO15693Transponder types,
which are described in chapter
ers.
REQUEST-DATA
4
0x24
MODE
RESPONSE-DATA (STATUS = 0x03)
5
DB-ADR-E
RESPONSE-DATA (STATUS = 0x95)
5
ISO15693
DB-ADR-E
ERROR
MODE:
Bit:
Function
ADR:
b000
b001
b010
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
DB-ADR:
Address of the first data block to be written to the Transponder. First block can be any value
between 0 and 255.
DB-N:
Number of data blocks to be written to the Transponder, starting at DB-ADR.
The maximum number of DB-N, depends on DB-Size and the interface receiver buffer size
RX-BUF. The maximum number of DB-N is:
(RX-BUF - 10 )/(DB-Size+1)
FEIG ELECTRONIC GmbH
System-Manual
9.1. Supported ISO15693 Host commands for ISO15693
5
(6...13)
UID
6
7
6
0
0
non-addressed
addressed
selected
6 / (14)
7 / (15)
DB-ADR
DB-N
5
4
0
0
Page 59 of 118
ID ISC.MR/PR/PRH100/101-A
8 / (16)
9...n / (17...n)
DB-SIZE
Repeated DB-
3
2
1
0
ADR
H01000-5e-ID-B.doc
Transpond-
DB
N times
0