DB:
Data of the data blockto be written to the Transponder. The required block size is defined by
DB-SIZE. The number of the expected bytes are DB-N * DB-SIZE.
ISO-ERROR: (only ISO15693 Transponders)
ISO15693 error code of Transponder response. This byte is only available if STATUS = 0x95.
DB-ADR-E:
Block number where the error occurred.

8.1.3. [0x90] Write Byte

This command locks one or more data blocks. The user can decide to use the customer command or
the command in ISO-Mode ([0x22] Lock Multiple Blocks).
REQUEST-DATA
5
0x90
MODE
RESPONSE-DATA (STATUS = 0x03)
5
DB-ADR-E
RESPONSE-DATA (STATUS = 0x95)
5
ISO-ERROR
DB-ADR-E
MODE:
Bit:
Function
ADR:
b000
b001
b010
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed mode.
DB-ADR:
First block number to be locked. First block can be any value between 0 and 255.
DB-N:
Number of data blocks to be locked, starting at DB-ADR. The maximum number of DB-N = 16
(128 bytes).
ISO-ERROR:
ISO15693 error code of Transponder response. This byte is only available if STATUS = 0x95.
DB-ADR-E:
Block number where the error occurred.
FEIG ELECTRONIC GmbH
System-Manual
6
(7...14)
UID
6
7
6
0
0
non-addressed
addressed
selected
7 / (15)
8 / (16)
DB-ADR
DB-N
5
4
0
0
Page 77 of 118
ID ISC.MR/PR/PRH100/101-A
3
2
1
0
ADR
H01000-5e-ID-B.doc