Feig Electronic OBID i-scan ID ISC.MR100 Manual page 58

Standard-reader
Table of Contents

Advertisement

®
OBID i-scan
DB-SIZE:
Number of bytes of one data block. This value depends on the specification of the Trans-
ponder manufacturer, see chapter
Transponders.
SEC-STATUS:
Block security status of followed data block. If supported by the ISO15693 transponder.
I-Code 1 Transponder doesn't support this function.
DB:
Requested data block. The block size is defined by DB-SIZE.
Notes:
• A read from 1 block uses a Read Single Block command to the Transponder.
• If a Transponder does not support Read Multiple Blocks commands several Read Single
Block commands are used for this Transponder.
• Only one Transponder can be read in the non-addressed mode.
• I-Code 1 and Tag-it HF Transponders cannot be read in the selected mode.
• An addressed read on the I-Code1 needs an
the transponder, even if the UID is known.
• USB-reader: If the reader is set to 8 timeslots (for I-Code 1) a maximum of 5 blocks can be
read from an I-Code 1 transponder with one read command.
• A non-addressed read on the I-Code1 cannot be performed if the transponder was selected
by an inventory command first. It must be deselected by using the command
Reset
FEIG ELECTRONIC GmbH
System-Manual
9.1. Supported ISO15693 Host commands for ISO15693
6.1.1. [0x01] Inventory
Page 58 of 118
ID ISC.MR/PR/PRH100/101-A
command first to select
5.6. [0x69] RF
H01000-5e-ID-B.doc