Feig Electronic OBID i-scan ID ISC.MR100 Manual page 30

Standard-reader
Table of Contents

Advertisement

®
OBID i-scan
SCAN-MODE
selects the data types to be send in the Scan Mode.
Bit:
Function
Notes:
If the bits UID and DB are set to 0, the scan-mode is switched off.
UID = Serial No.
Setting of this bit activates the output of the UID
b0
b1
DB = Data Block
Setting of this bit activates the output of a specified data field.
b0
b1
COM Prefix
When this option is on, the Reader will transmit the COM-ADR before each data set.
b0
b1
Byte Order
Defines the Byte Order within frame
b0
b1
Note:
IF the COM Prefix is enabled the COM-ADR will be send in front of the Header
FEIG ELECTRONIC GmbH
System-Manual
Note
If Trigger is enabled an not activated by the external switch, the RF-
field will be switched off.
7
6
5
Byte
COM-
0
Order
Prefix
Output of the UID inactive
Output of the UID active
Output of a data field inactive
Output of a data field active
COM-ADR of the Reader will not transmit
COM-ADR of the Reader will transmit
MSB first
LSB first
Page 30 of 118
4
3
2
0
0
0
ID ISC.MR/PR/PRH100/101-A
1
0
DB
UID
H01000-5e-ID-B.doc

Advertisement

Table of Contents
loading

Table of Contents