EOF-PULSE-DELAY:
EOF Pulse delay is used in write operations with ISO15693 write option "1". EOF to define
the in response delay for Transponder response (ISO15693: t1)
e.g. ISO15693 maximum value: 0x846A * 590ns = 20ms
REQUEST-DATA:
Complete Transponder request without SOF, CRC16 and EOF
Note:
• The read and write option FLAGS in the REQUEST-DATA must correspond to the
MODE Byte in the request protocol. Reader is always forcing the command in the
way specified by MODE Byte in the request protocol
RESPONSE-DATA:
Complete Transponder response without SOF and EOF. A CRC16 check is performed inside
the Reader. However the Transponder CRC16 is transferred with the response data.
Notes:
• Data is only transferred if STATUS = 0x00, 0x83, 0x94, 0x95.
• The response data ever contain the in RSP-LENGTH defined number of data bytes.
Note:
• This command is only available for ISO15693 Transponders.
• This command is not available if the Scan-Mode is witched on.
FEIG ELECTRONIC GmbH
System-Manual
Page 89 of 118
ID ISC.MR/PR/PRH100/101-A
H01000-5e-ID-B.doc