8.3. Philips ISO15693 I-Code SLI Custom Commands

8.3.1. [0xA2] Set EAS

This command sets the EAS bit to 1.
REQUEST-DATA
5
0xA2
MODE
RESPONSE-DATA (STATUS = {0x95})
5
ISO-ERROR
MODE:
Bit:
Function
ADR:
UID:
Read-only serial number of the transponder. The UID is required only in the addressed mode.
ISO-ERROR:
ISO error code of transponder response. This byte is only available if STATUS = {0x95}.

8.3.2. [0xA3] Reset EAS