Time Behavior for [0x01] Inventory and ISO15693 Transponders

All times apply to the following parameters: ISO15693 MODE = 0x0B (see
Parameters) and
3.6. CFG5:
AFI disabled
16 timeslots
only ISO15693 Transponder driver active
ONT = Only new Transponder will be send to the host
The modulation and the sub-carrier have a negligible influence on the reaction time.
The following diagrams shows the average value of timing behavior, dependent on the number of
Transponders. For certain UID's the real timing can by higher or lower as show below.
The timing is measured inclusive of the communication time at 38,4Kbaud. A modified baud rate will
slightly increase the timing but the Inventory timing is mostly determined by anticollision so you may
neglect the communication time.
FEIG ELECTRONIC GmbH
System-Manual
Anticollision.
Execution time
Tx
Rx
Communication time
Page 106 of 118
+
=