OBID i-scan
GRN / RED / BUZZER
Startup Buzzer / LED (only idle state)
When this option is selected, the Reader will switch the BUZZER and the LEDs on
for two seconds to indicate that the Reader is ready after the Reader is supplied with
power. If the Reader is reset by software, only both LEDs switch on for 2 seconds.
IDLE-FLASH / ACTIV-FLASH:
By means of the two bytes "IDLE-FLASH" and "ACTIV-FLASH" the signal transmitter may be pro-
vided with an own flashing frequency for idle and active position.
Bit:
Function:
Bit combination
b11
b10
b01
b00
ACTIV-xxx-TIME
If a Transponder was detected, the transmitter and the duration can be set by the bytes ACTIV-STATE
and ACTIV-FLASH. Each signal transmitter (LED, BUZZER) may be activated temporarily limited.
Signal transmitter
ACTIV-GRN-TIME
ACTIV-RED-TIME
ACTIV-BUZZER-TIME
FEIG ELECTRONIC GmbH
System-Manual
Bit Combination
b00
b01
b10
b11
7
6
5
0
0
flashing frequency
1 Hz
2 Hz
4 Hz
8 Hz
Signal device
unchanged
on
off
flashing
4
3
BUZZER
time range
0...255 x 100 ms
0...255 x 100 ms
0...255 x 100 ms
Page 23 of 118
ID ISC.MR/PR/PRH100/101-A
2
1
RED
GRN
H01000-5e-ID-B.doc
0