0X2C] Get Multiple Block Security Status - Feig Electronic OBID i-scan ID ISC.MR100 Manual

Standard-reader
Table of Contents

Advertisement

®
OBID i-scan

6.1.13. [0x2C] Get Multiple Block Security Status

This command reads the public block security status from one Transponder.
REQUEST-DATA
4
0x2C
MODE
RESPONSE-DATA (STATUS = 0x95)
5
ISO15693
ERROR
RESPONSE-DATA
5
DB-N
SEC-STATUS
Repeated DB-
N times
MODE:
Bit:
Function
ADR:
b000
b001
b010
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed mode.
DB-ADR:
First block number from which security status is requested. First block number can be any
value between 0 and 255.
DB-N:
Number of Security data blocks to be read from the Transponder, starting at DB-ADR.
The maximum number of DB-N, depends on DB-Size.
DB-Size
4
8
x
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS =
0x95.
SEC-STATUS:
Block security status .
Note:
This command is only available for ISO15693 Transponders.
FEIG ELECTRONIC GmbH
System-Manual
5
(6...13)
UID
6
7
6
0
0
non-addressed
addressed
selected
Max. DB-N
0x20 ->32
0x10 ->16
= 128 / x
6 / (14)
7 / (15)
DB-ADR
DB-N
5
4
0
0
Page 69 of 118
ID ISC.MR/PR/PRH100/101-A
3
2
1
0
ADR
H01000-5e-ID-B.doc
0

Advertisement

Table of Contents
loading

Table of Contents