OBID i-scan

8.1. Infineon Custom Commands

This commands supports the functions of the Infineon transponder

8.1.1. [0x10] Read

This command reads one or more data blocks. The user can decide to use the customer command or
the command in ISO-Mode ([0x23] Read Multiple Blocks).
REQUEST-DATA
5
0x10
MODE
RESPONSE-DATA (STATUS = 0x95)
5
ISO-ERROR
RESPONSE-DATA
5
DB-N
DB-SIZE
MODE:
Bit:
Function
ADR:
b000
b001
b010
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
DB-ADR:
First block number to be read. First block can be any value between 0 and 255.
DB-N:
Number of data blocks to be read from the Transponder, starting at DB-ADR.
The maximum number of DB-N is 16 (128 bytes)
ISO-ERROR: (only ISO15693 Transponders)
ISO15693 error code of Transponder response. This byte is only available if STATUS = 0x95.
DB-SIZE:
Number of bytes of one data block(8 Bytes).
SEC-STATUS:
Block security status of followed data block. Sec-Status is not supported, this value will return
0x00.
FEIG ELECTRONIC GmbH
System-Manual
6
(7...14)
UID
6
7
SEC-STATUS
Repeated DB-N times
7
6
0
0
non-addressed
addressed
selected
7 / (15)
8 / (16)
DB-ADR
DB-N
8...n
DB
5
4
0
0
Page 75 of 118
ID ISC.MR/PR/PRH100/101-A
3
2
1
0
ADR
H01000-5e-ID-B.doc
0