0X71] Set Output - Feig Electronic OBID i-scan ID ISC.MR100 Manual

Standard-reader
Table of Contents

Advertisement

®
OBID i-scan

5.8. [0x71] Set Output

The command [0x71] is used for temporary limited or unlimited activation of the digital outputs or dis-
plays (LED, beeper) of the Reader.
Each output takes on the state defined by the byte "OS" for the period of time specified in the protocol.
The flashing frequency is defined by the byte "OSF". Via this protocol, the beeper and the LEDs can
be switched on or off for the indicated period of time. If the Reader receives a protocol "Set Output", all
times that have been active until then are overwritten by the new times specified in the protocol if they
are > 0.
Host → Reader
1
13
COM-Adr
Host ← Reader
1
6
COM-Adr
OS:
The word OS (Output State) defines the status of the signal emitters (LEDs and beeper) dur-
ing the time defined in "OS-time". The signal emitters can be selected single or in a group.
Bit:
Function:
LED grn-/LED red-/Beeper-mode:
b00
b01
b10
b11
1
see ANNEX D: Index of Status Bytes
FEIG ELECTRONIC GmbH
System-Manual
2
3
[0x71]
2
3
[0x71]
15
14
13
0
0
0
7
6
5
0
0
Beeper mode
(only PRH100)
UNCHANGED
OS-Time has no effect on the status of the signal emitter
ON
Signal emitter for OS-Time = active
OFF
Signal emitter for OS-Time = inactive
FLASH
Signal emitter for OS-Time = with "OSF" alternating
Page 48 of 118
4,5
6,7
OS
OSF
8,9
10,11
OS-Time
0x00
4
5,6
1
CRC16
Status
12
11
10
0
0
0
4
3
2
LED red
mode
ID ISC.MR/PR/PRH100/101-A
12,13
CRC16
9
8
0
0
1
0
LED grn
mode
H01000-5e-ID-B.doc

Advertisement

Table of Contents
loading

Table of Contents