Data Transmission Between Obid; I-Scan Id Isc.mr/Pr/Prh100 And Host; Configuration Commands And Control Commands - Feig Electronic OBID i-scan ID ISC.MR100 Manual

Standard-reader
Table of Contents

Advertisement

®
OBID i-scan

1. Data Transmission between OBID

For different ways of data transmission between OBID
possible. The ISO15693Host Commands and the Scan Mode are used for the data exchange be-
tween Transponder and host, whereas the Configuration Commands and the Control serves for
adapting the Reader parameters to the individual range of applications. The following chart shows
which method of data transmission is supported by which interface:
Configuration Commands
Control Commands
ISO15693Host Commands
Scan-Mode

1.1. Configuration Commands and Control Commands

This method of data transmission is used for Reader configuration and the diagnosis via the asyn-
chronous interface or USB.
The Reader-configuration parameters will be stored in the Reader memory. To store the current con-
figuration during a power down of the Reader, the Reader-Configuration must be stored in the
EEPROM. After power up the Reader reads the configuration out of the EEPROM.
The Reader control is immediately processed and the response from the Reader contain status or
data information of the control command.
Host (Terminal / PC / ....)
parameter- / control command
FEIG ELECTRONIC GmbH
System-Manual
®

i-scan ID ISC.MR/PR/PRH100 and Host

®
i-scan Readers and host (terminal, PC) are
asynchronous interface
(RS232 / RS485)
parameter received and stored / control
command processed
yes
status /
data
Page 9 of 118
ID ISC.MR/PR/PRH100/101-A
Reader
no
error status
H01000-5e-ID-B.doc

Advertisement

Table of Contents
loading

Table of Contents