Fig. Left underside of the machine
1. Drain plug
1
Fig. Hydraulic reservoir, bottom
1. Drain plug
206
Maintenance, 3000 / 5000 / 7000 h

Fuel tank - Draining (Equipment status)

Water and sediment in the fuel tank are drained out
via the drain plug (1) in the bottom of the fuel tank.
Be very careful during draining. Do not drop the
Be very careful during draining. Do not drop the
plug or else all the fuel will flow out.
plug or else all the fuel will flow out.
Drain the roller after it has been stationary for a long
time, e.g. after standing overnight. The fuel level
should be as low as possible.
The roller should preferably have been standing with
the drain plug somewhat lower, so that water and
sediment collect at the drain plug (1). Drain as follows:
Place a container under the plug (1).
Undo the drain plug (1) and drain out water and
sediment until only pure diesel fuel comes out at the
plug. Screw in the plug again.

Hydraulic reservoir - Draining

Condensate in the hydraulic reservoir is drained via
the drain plug (1).
Drain the roller after it has been stationary for a long
time, e.g. after standing overnight. Drain as follows:
Place a container under the drain hole.
Remove the plug (1).
Drain off any condensate.
Refit the plug.