Air filter indicator - Resetting
The air filter indicator is located on the filter,
or in its immediate vicinity.
The air filter indicator must be reset after replacing
the air filter.
Press the "button" (1) on the top of the indicator
to reset.
Backup filter - Change
Change the backup filter with a new filter after every
third replacement of the main filter.
To change the backup filter (1), pull the old filter out of
its holder, insert a new filter and reassemble the air
cleaner in the reverse order.
Clean the air cleaner if necessary.
See section Air cleaner - Cleaning.
Compressor belt - Adjustment
Loosen the two screws (1) at the top of the cover plate
(3) and remove it.
The belt (2) is now slackened and can be adjusted.
Tighten the belt to 10 mm (3/8 in.).
When the belt is tensioned, refit the cover plate (3)
and tighten the screws (1).
2
4812165001.pdf
Maintenance, 6000h