Fig. Engine compartment
1. Hydraulic fluid filter (x1).
208
Maintenance, 3000 / 5000 / 7000 h
Carefully clean round the filter.
Remove the oil filter (1) and hand in to an
Remove the oil filter (1) and hand in to an
environment-friendly waste disposal station.
environment-friendly waste disposal station.
This is a disposable filter and cannot be cleaned.
This is a disposable filter and cannot be cleaned.
Make sure that the old sealing ring is not left on
Make sure that the old sealing ring is not left on
the filter holder. Otherwise, this could cause
the filter holder. Otherwise, this could cause
leakage between the new and old seal.
leakage between the new and old seal.
Thoroughly clean the sealing surfaces on
the filter holder.
Apply a thin coat of fresh hydraulic fluid to the seals
on the new filter and screw tight the filter by hand.
First tighten the filter until its seal is in contact
First tighten the filter until its seal is in contact
with the filter attachment. Then turn an additional
with the filter attachment. Then turn an additional
half revolution. Do not tighten the filter too hard
half revolution. Do not tighten the filter too hard
as this could damage the gasket.
as this could damage the gasket.
Start the engine and check that there is
no leakage of hydraulic fluid from the filter.
Check the fluid level in the sight glass
and top up if necessary.
Ensue that there is good ventilation
Ensue that there is good ventilation
(air extraction) if the engine is run indoors.
(air extraction) if the engine is run indoors.
Risk of carbon monoxide poisoning.
Risk of carbon monoxide poisoning.