Cabling
HPE ProLiant Gen10 DX Servers Storage Cabling Guidelines
When installing cables, observe the following:
•
All ports are labeled:
◦
System board ports
◦
Controller ports
◦
12G SAS Expander ports
•
Most data cables have labels near each connector with destination port information.
•
Some data cables are pre-bent. Do not unbend or manipulate the cables.
•
Before connecting a cable to a port, lay the cable in place to verify the length of the cable.
•
When routing cables from the front to the rear of the server, use the cable channels on either side of the chassis.
Cabling diagrams
Use the following tables to find cabling information and diagrams.
Table 3: SAS/SATA kits
Option kit
Front 2SFF SAS/SATA drive cage (SFF) 869826-001
Front 2SFF SAS/SATA 1U drive cage
(LFF)
Front 8SFF SAS/SATA drive cages
Cable part number*
From
1
Drive backplane
1
869826-001
Drive backplane
4
776402-001
Drive backplane
To
Power cable part
number
System board
869810-001
SAS Expander
869825-001
Controller
869810-001
System board
SAS Expander
Controller
869825-001
System board
SAS Expander
Controller
Table Continued
Cabling
6
6
6
6
156