HPE ProLiant DX380 Gen10 User Manual page 16

Table of Contents

Advertisement

Systems Insight Display LED
and color
DIMM (amber)
Over temp (amber)
Over temp (amber)
PCI riser (amber)
Fan (amber)
Fan (amber)
Power supply (amber)
Power supply (amber)
Power cap (off)
Power cap (green)
Power cap (green)
Power cap (flashing amber)
IMPORTANT: If more than one DIMM slot LED is illuminated, further troubleshooting is required. Test each bank of
DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing each DIMM in a bank with a known
working DIMM.
Health LED System power
LED
Amber
Green
Amber
Green
Red
Amber
Red
Green
Amber
Green
Red
Green
Red
Amber
Amber
Green
Amber
Flashing green
Green
Amber
Status
DIMM in slot X is in a pre-failure condition.
The Health Driver has detected a
cautionary temperature level.
The server has detected a hardware critical
temperature level.
The PCI riser cage is not seated properly.
One fan has failed or has been removed.
Two or more fans have failed or been
removed.
One or more of the following conditions
might exist:
Only one power supply is installed and
that power supply is in standby.
Power supply fault.
System board fault.
One or more of the following conditions
might exist:
Redundant power supply is installed and
only one power supply is functional.
AC power cord is not plugged into
redundant power supply.
Redundant power supply fault.
Power supply mismatch at POST or
power supply mismatch through hot-
plug addition.
Standby.
Waiting for power.
Power is available.
Power is not available.
Component identification
16

Advertisement

Table of Contents
loading

Table of Contents