Installing a rear 3LFF SAS/SATA drive cage

Before installing this option, the front bays must be fully populated with 12 LFF drives. High-performance fans must be
installed in all fan bays.
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
T-10 Torx screwdriver
The components included with the hardware option kit
Procedure
1.
Power down the server.
2.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3.
Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
4.
Remove the access panel.
5.
If installed, remove the secondary riser cage. The secondary riser cage is not supported with a three-bay LFF rear
configuration.
6.
Remove the rear wall blank.