Objet260 User Guide
If the UV level measured is not acceptable, the wizard calibrates the UV lamp 
by adjusting the current supplied to it, and then tests it again.
When all UV tests have finished, the results are displayed, showing the 
condition of the lamps after calibration (see Figure 6-100 below).
Figure 6-100    Results and condition of UV lamps after calibration
After examining the UV calibration results:
1.  Click Next.
2.  Remove the UV sensor and close the printer cover. After confirming the 
DOC-37004 Rev. J
items listed in the wizard screen, click Next.
If the results are not acceptable for quality printing, this is indicated in the 
final wizard screen.
Figure 6-101    Final UV Calibration Wizard screen