➢   If the replacement head was not calibrated by Stratasys, remove the head 
Testing and Calibrating the UV Lamps
The level of UV radiation from the lamps used for curing 3D prints can change 
over time. To ensure optimum curing of 3D prints during printing, a pop-up 
message reminds you to test the lamps and calibrate the level of UV radiation 
after every 300 hours of printing. You do this by running the UV Calibration 
Wizard.
To measure the UV radiation, you need:
• Stratasys TOL-03005-S (UV sensor and cable)
• a stand-alone UV radiation meter, approved for use with the printer
The wizard compares the measured radiation to the recommended radiation 
level for each of the lamps, at each printing mode—High Speed and 
High Quality / Digital Material.
When calibrating the lamps, the wizard attempts to adjust the radiation level, if 
necessary.
• If the reading is within the acceptable range, the wizard continues to the 
• If further adjustment is necessary, the current phase is repeated. 
• If the level of UV radiation is too low to be properly adjusted, the wizard 
Before testing and calibrating the UV lamps: 
 
l
 
l
DOC-37004 Rev. J
and replace it with another one. 
Figure 6-88    Invalid-head warning
Contact your Stratasys service provider about the uncalibrated head.
or—
next phase. 
continues to the next phase, but the final wizard screen indicates that the 
lamp's radiation for the printing mode is unacceptable.
Make sure the glass lens on each of the UV lamps is clean. For easy 
access, run the Head Cleaning Wizard, and use the special sanding 
sponge supplied in the Start-Up Kit.
Make sure that the glass over the UV radiation sensor is clean.
6 Operating and Maintaining the Printer
6-64