Objet260 User Guide
8. For each column of lines, use a magnifying glass or loupe to inspect pairs of
DOC-37004 Rev. J
Figure 6-51    Sample head-alignment test
Note:  There is no column for head H7 because its alignment is used as a 
reference for aligning all other heads.
consecutive rows printed on the transparency to see where the vertical
lines align.
Figure 6-52    Comparing rows of alignment lines
Note:  It does not matter which pair of lines you inspect, since they were all 
printed by the same head. Choose a pair of clearly printed lines for the 
inspection. (Since some nozzles may not print clearly, you may have to 
inspect several pairs of lines to properly view the alignment.)
Optimum head alignment is shown when the fourth lines in the upper and 
lower rows are aligned, as in Figure 6-52. In the example shown, no change 
to the head alignment is necessary. If other lines in the set are aligned, you 
need to change the alignment of that head—in the next wizard screens.