If, during the optimization process, the wizard determines that a print head is 
faulty—or that it is negatively affecting layer uniformity with the current head 
configuration—the wizard instructs you to replace it. If this happens, you can 
continue the wizard to replace the print head, or abort the wizard, to replace the 
head at another time. 
Run the Head Optimization wizard every 300 hours of printing or whenever 
the condition of print heads is negatively affecting the quality of 3D prints, or 
if you suspect that there is a problem with one or more of the print heads.
Note:  Allow at least 40-50 minutes per mode   f or performing this procedure 
(not including time required for replacing faulty print heads). To accurately test 
and calibrate print heads, they must be clean. If necessary, run the Head 
Cleaning wizard before beginning this procedure.
To test and calibrate the print heads:
1.  Prepare—
2.  Check that there is a material cartridge loaded in the M3 slot. If necessary, 
3.  Start the Head Optimization wizard from the Options menu.
4.  In the opening wizard screen, click Next to begin.
DOC-37004 Rev. J
❒   disposable cleaning gloves (any clean, powder-free protective gloves)
❒   pink paper
❒   the Missing Nozzles ruler
❒   the scale supplied for use in the Head Optimization wizard
Important:  Before beginning this procedure, ensure that the scale is 
calibrated and at least partially charged. 
insert a cartridge that contains different material than is loaded in the other 
slots, or insert a cleanser cartridge.
Note:  The Head Optimization wizard will not operate if the M3 cartridge 
slot is empty.
Figure 6-56    Starting the Head Optimization wizard
The Wizard Conditions screen appears.
6 Operating and Maintaining the Printer
6-47