HPE ProLiant DL388 Gen10 User Manual page 27

Hide thumbs Also See for ProLiant DL388 Gen10:
Table of Contents

Advertisement

CAUTION: Do not remove an NVMe SSD from the drive bay while the Do not remove LED is flashing.
The Do not remove LED flashes to indicate that the device is still in use. Removing the NVMe SSD
before the device has completed and ceased signal/traffic flow can cause loss of data.
Item LED
Status
1
Locate
Solid blue
Flashing blue
2
Activity
Rotating green
ring
Off
3
Drive
Solid green
status
Flashing green
Flashing amber/
green
Flashing amber The drive is not configured and predicts the drive will fail.
Solid amber
Off
4
Do not
Solid white
remove
Flashing white
Off
5
Power
Solid green
Definition
The drive is being identified by a host application.
The drive carrier firmware is being updated or requires an update.
Drive activity
No drive activity
The drive is a member of one or more logical drives.
The drive is doing one of the following:
Rebuilding
Performing a RAID migration
Performing a stripe size migration
Performing a capacity expansion
Performing a logical drive extension
Erasing
The drive is a member of one or more logical drives and predicts the
drive will fail.
The drive has failed.
The drive is not configured by a RAID controller.
Do not remove the drive. The drive must be ejected from the PCIe bus
prior to removal.
The drive ejection request is pending.
The drive has been ejected.
Do not remove the drive. The drive must be ejected from the PCIe bus
prior to removal.
Table Continued
Component identification
27

Advertisement

Table of Contents
loading

Table of Contents