CAUTION: Electrostatic discharge can damage electronic components. Be sure you are properly
grounded before beginning this procedure.
CAUTION: Failure to properly handle DIMMs can damage the DIMM components and the system board
connector. For more information, see the DIMM handling guidelines in the troubleshooting guide for your
product on the Hewlett Packard Enterprise website:
HPE ProLiant Gen10 (http://www.hpe.com/info/gen10-troubleshooting)
HPE Synergy (http://www.hpe.com/info/synergy-troubleshooting)
CAUTION: Unlike traditional storage devices, NVDIMMs are fully integrated in with the ProLiant server.
Data loss can occur when system components, such as the processor or HPE Smart Storage Battery,
fails. HPE Smart Storage battery is a critical component required to perform the backup functionality of
NVDIMMs. It is important to act when HPE Smart Storage Battery related failures occur. Always follow
best practices for ensuring data protection.
Prerequisites
Before installing an NVDIMM, be sure the server meets the Server requirements for NVDIMM support on
page 81.
Procedure
1.
Power down the server.
2.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3.
Do one of the following:
a. Extend the server from the rack.
b. Remove the server from the rack.
4.
Remove the access panel.
5.
If the Smart Storage battery is not installed, do one of the following:
Remove the air baffle.
If installed on LFF models, remove the midplane drive cage.
6.
Locate any NVDIMMs already installed in the server.
7.
Verify that all LEDs on any installed NVDIMMs are off.
8.
Install the NVDIMM.