Installing a rear 3LFF SAS/SATA drive cage

Before installing this option, the front bays must be fully populated with 12 LFF drives. High-performance fans
must be installed in all fan bays.
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
T-10 Torx screwdriver
The components included with the hardware option kit
Procedure
1.
Power down the server.
2.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3.
Do one of the following:
Extend the server from the rack.
Remove the server from the rack .
4.
Remove the access panel.
5.
If installed, remove the secondary riser cage. The secondary riser cage is not supported with a three-bay
LFF rear configuration.
6.
Remove the rear wall blank.
110
Hardware options installation