Speed Limit (Frequency Reference Limit Func-
tion)
This section explains how to limit the motor speed.
Limiting Maximum Output Frequency
If you do not want the motor to rotate above a given frequency, use parameter d2-01.
Set the upper limit value of the Inverter output frequency as a percent, taking E1-04 (Maximum Output Fre-
quency) to be 100%.
Related Parameters
Name
Param-
eter
Number
Display
Frequency
reference
upper limit
d2-01
Ref Upper
Limit
Limiting Minimum Frequency
If you do not want the motor to rotate at below a given frequency, use parameters d2-02 or d2-03.
There are two methods of limiting the minimum frequency, as follows:
Adjust the minimum level for all frequencies.
•
Adjust the minimum level for the master speed frequency (i.e., the lower levels of the jog frequency, multi-
•
step speed frequency, and auxiliary frequency will not be adjusted).
Related Parameters
Name
Param-
eter
Number
Display
Frequency
reference
lower limit
d2-02
Ref Lower
Limit
Master
speed refer-
ence lower
d2-03
limit
Ref1 Lower
Limit
Description
Set the output frequency
upper limit as a percent, tak-
ing the max. output fre-
quency to be 100%.
Description
Sets the output frequency
lower limit as a percentage
of the maximum output fre-
quency.
Set the master speed refer-
ence lower limit as a percent,
taking the max. output fre-
quency to be 100%.
Speed Limit (Frequency Reference Limit Function)
Control Methods
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0.0 to
100.0%
No
A
110.0
Control Methods
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0.0 to
0.0%
No
A
110.0
0.0 to
0.0%
No
A
110.0
Regis-
V/f
Open
Flux
ter
with
Loop
Vec-
PG
Vector
tor
A
A
A
289H
Regis-
V/f
Open
Flux
ter
with
Loop
Vec-
PG
Vector
tor
A
A
A
28AH
A
A
A
293H
41
6-