Removing and Mounting the Control Circuit Terminal Board

The control circuit terminal board can be removed and mounted without disconnecting the cables.
IMPORTANT
Removing the Control Circuit Terminal Board
1. Remove the Digital Operator and front cover.
2. Remove the connecting line connectors connected to FE and NC on the control circuit terminal board.
3. Loosen the mounting screws (1) on the left and right sides of the control terminals until they are free. (It is
not necessary to remove these screws completely. They are self-rising.)
4. Pull the terminal board out sideways (in direction 2) with the screws sticking out from the board.
Mounting the Control Circuit Terminal Board
Reverse the removal procedure to mount the terminal board.
Confirm that the control circuit terminal board and the control board properly meet at connector CN5 before
pressing in on the board.
The connector pins may be bent if the board is forced into place, possibly preventing correct Inverter opera-
tion.
-20
8
Always confirm that the charge indicator is not lit before removing or mounting the control circuit terminal
board.
Fig 8.17 Removing the Control Circuit Terminal Board