Using an Analog Operator

This example shows wiring for using an Analog Operator. The Analog Operator model number is 3G3IV-
PJVOP95
or 3G3IV-PJVOP96 .
This example shows wiring for the 3G3RV-A2075 (200-V class Inverters of 7.5 kW)
MCCB
3-phase power
3G3IV-PJVOP-95 /3G3IV-PJVOP-96
Frequency meter
Short-circuit bar
(Standard)
R/L1
Inverter
S/L2
T/L3
Forward run command
(forward run when closed)
Reverse run command
(reverse run when closed)
Multi-function contact inputs
Sequence common (0 V)
Shield terminal
Speed setting power (15 V, 20 mA)
Master speed (0 to 10 V, 20 kΩ)
Master speed (4 to 20 mA, 250 Ω)
Multi-function contact
output (Default: Running
signal)
Fault contact output
Multi-function
analog output
Multi-function
analog output
(Default: Output
frequency)
Fig 10.13
Motor
U/T1
V/T2
W/T3
Ground to 100 Ω max.
Open collector 1 (Default:
Zero speed signal)
Open collector 2 (Default:
Speed agreement signal)
Multi-function output
common
Wiring Examples
Multi-function open-
10
collector output 48 V,
50 mA max.
23
10-