Raising And Lowering Frequency References Using Contact Signals (Up/Down) - Omron SYSDRIVE RV Series User Manual

High-function general-purpose inverters
Table of Contents

Advertisement

Application Precautions
When d4-01 is set to 1, the output frequency on hold is stored even after the power supply is turned OFF. If
performing operations using this frequency after the Inverter has also been turned OFF, input the Run
Command with the Acceleration/Deceleration Ramp Hold turned ON.
When d4-01 is set to 0 and a Run Command is input while the Acceleration/Deceleration Ramp Hold is
turned ON, the output frequency will be set to zero.
If you input an Acceleration/Deceleration Ramp Hold command by error when decelerating during posi-
tioning, deceleration may be canceled.
Raising and Lowering Frequency References Using Contact Signals (UP/
DOWN)
The UP and DOWN commands raise and lower Inverter frequency references by turning ON and OFF a multi-
function contact input terminal S3 to S8.
To use this function, set one of the parameters H1-01 to H1-06 (multi-function contact input terminal S3 to S8
function selection) to 10 (UP command) and 11 (DOWN command). Be sure to allocate two terminals so that
the UP and DOWN commands can be used as a pair.
The output frequency depends on the acceleration and deceleration time. Be sure to set b1-02 (Run Command
selection) to 1 (Control circuit terminal).
Related Parameters
Param-
eter
Number
Frequency
reference
upper limit
d2-01
Ref Upper
Limit
Frequency
reference
lower limit
d2-02
Ref Lower
Limit
Master
speed refer-
ence lower
d2-03
limit
Ref1 Lower
Limit
-84
6
Name
Description
Display
Set the output frequency
upper limit as a percent, tak-
ing the max. output fre-
quency to be 100%.
Sets the output frequency
lower limit as a percentage
of the maximum output fre-
quency.
Set the master speed refer-
ence lower limit as a percent,
taking the max. output fre-
quency to be 100%.
Control Methods
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0.0 to
100.0%
No
A
110.0
0.0 to
0.0%
No
A
110.0
0.0 to
0.0%
No
A
110.0
Regis-
V/f
Open
Flux
ter
with
Loop
Vec-
PG
Vector
tor
A
A
A
289H
A
A
A
28AH
A
A
A
293H