Storing Inverter set values in the Digital Operator (READ)
To store Inverter set values in the Digital Operator, make the settings using the following method. Set 03-02
(Read permitted selection) to 1 (read permitted).
Step
No.
1
2
3
4
5
6
7
An error may occur while saving to memory. If an error is displayed, press any key to cancel the error display
and return to the o3-01 display. Error displays and their meanings are shown below. (Refer to Chapter 7
Errors when Using Digital Operator Copy Function.)
Error Display
Select READ Permitted
Prevent overwriting the data stored in EEPROM in the Digital Operator by mistake. With o3-02 set to 0, if you
set o3-01 to 1, and perform the write operation, PrE will be displayed on the Digital Operator, and the write
operation will be stopped.
-186
6
Table 6.5 READ Function Procedure
Digital Operator Display
You are attempting to set o3-01 to 1 while o3-02 is set to 0.
Read data length mismatch or read data error.
Tried to write parameters to EEPROM on the Digital Operator, but unable to perform write opera-
tion.
Explanation
Press the Menu Key, and select advanced pro-
gramming mode.
Press the DATA/ENTER Key, and select the
parameters monitor display.
Display o3-01 (Copy Function Selection) using
the Increment Key and Decrement Key.
Press the DATA/ENTER Key, and select the
parameters setting display.
Change the set value to 1 using the Increment
Key.
Set the changed data using the DATA/ENTER
Key. The READ function will start.
If the READ function ends normally, End is
displayed on the Digital Operator. Parameter
o3-01 is automatically reset to 0, and then the
display returns to o3-01.
Meaning