Prohibiting Writing Parameters from the Digital Operator

If you set A1-01 to 0, you can refer to and set the A1 and A2 parameter groups, and refer to drive mode, using
the Digital Operator.
If you set one of the parameters H1-01 to H1-06 (multi-function contact input terminal S3 to S8 function
selection) to 1B (write parameters permitted), you can write parameters from the digital operator when the ter-
minal that has been set is ON. When the set terminal is OFF, writing parameters other than the frequency ref-
erence is prohibited. You can, however, reference parameters.
Name
Param-
eter
Display
Number
Used to set the parameter
access level (set/read.)
0: Monitoring only
(Monitoring drive mode
Parameter
and setting A1-01 and
access level
A1-04.)
1: Used to select user
parameter
A1-01
(Only parameters set in
A2-01 to A2-32 can be
read and set.)
2: Advanced
Access
(Parameters can be read
Level
and set in both quick
programming mode and
advanced programming
(A) mode.)

Setting a Password

When a password is set in A1-05, if the set values in A1-04 and A1-05 do not match, you cannot refer to or
change the settings of parameters A1-01 to A1-03, or A2-01 to A2-32.
You can prohibit the setting and referencing of all parameters except A1-00 by using the password function in
combination with setting A1-01 to 0 (Monitor only).
Setting
Description
Range
0 to 2
Digital Operator Functions
Control Methods
Change
Factory
during
V/f
Open
Setting
Opera-
V/f
with
Loop
tion
PG
Vector
2
Yes
A
A
Regis-
Flux
ter
Vec-
tor
A
A
101H
189
6-