Shunt Connector CN5 and DIP Switch S1
The shunt connector CN 5 and DIP switch S1 are described in this section.
The functions of DIP switch S1 are shown in the following table.
Name
S1-1
S1-2
-30
2
Fig 2.23 Shunt Connector CN5 and DIP Switch S1
Table 2.13 DIP Switch S1
Function
RS-485 and RS-422A terminating resis-
tance
Input method for analog input A2
CN5
S1
OFF
ON
O
1
F
2
F
V
I
: Factory settings
Note: Refer to Table 2.13 for S1
functions and to Table
2.14 for CN5 functions.
Setting
OFF: No terminating resistance
ON: Terminating resistance of 110 Ω
OFF: -10 to 10 V (internal resistance: 20 kΩ)
ON: 4 to 20 mA (internal resistance: 250 Ω)
Terminating resistance
Analog input switch