18 TROUBLESHOOTING

DISPLAY
The display does not turn on
The valves cannot be controlled
A valve does not open
The counting of the distance
traveled shown on the
Geosystem is different from the
actual distance.
The counting of the treated area
shown on the Geosystem is
different from the actual area.
The instant pressure is not
shown.
The displayed instant pressure is
inaccurate.
The displayed tank level is
inaccurate.
Table 9 - Troubleshooting
74
-
CAUSE
There is no power.
The monitor is turned off.
The valves are not connected.
There is no power going to the
valve.
Incorrect programming
The totalizer has not been reset
Incorrect programming
The totalizer has not been reset
The monitor is not receiving a
signal from the pressure sensor
Incorrect installation of the
pressure sensor
Incorrect programming
The pressure sensor has not
been calibrated
Incorrect installation of the
pressure sensor
The level sensor has not been
calibrated.
Incorrect installation of the level
sensor.
GeoSystem RevA6
SOLUTION
Check the power cable
connections.
Press the ON button.
Connect the connectors
Check the electric connection
and the functioning of the valve
Check the connection with the
speed sensor.
Reset the totalizer
Check the boom width
programming
Reset the totalizer
Check the connections with the
pressure sensor
Check the connections with the
pressure sensor
Check the full scale programming
for the pressure sensor
Perform the calibration
Check the connections with the
pressure sensor
Perform the calibration.
Repeat the level sensor
calibration.
Check the connection with the
level sensor