Configuration
12
Simulated speed value:
The monitor simulates the travel speed.
0-50 Km/h (metric) or mph (U.S.)
13
Manual min. speed:
0-50 Km/h (metric) or mph (U.S.)
Value below which, in manual mode,
the spraying is stopped by closing the
main valve.
14
Autom. min. speed:
0-50 Km/h (metric) or mph (U.S.)
Value below which, when operating in
automatic mode, the spraying is
stopped by closing the main valve.
15
Manual speed threshold:
0-50 Km/h (metric) or mph (U.S.)
Below this value, automatic dose
management is not performed. The
system changes to manual mode .
16
Pressure calculation:
Yes/No.
If the parameter is No, the pressure
sensor is used.
If the parameter is Yes, the operating
pressure is calculated as a function of
the current flow rate and the
characteristics of the nozzles
configured on each radial boom.
17
Number of section valves:
2, 4
36
-
GeoSystem RevA6